Classroom heat during the hottest term

Example desert town · North Africa (synthetic)

Date observed
11 Jun 2025
Last update
2 Jul 2026
Local contact
School management committee

Current status

  1. Observed

    Completed

  2. Verified

    Completed

  3. Open

    Completed

  4. Solution Proposed

    Completed

  5. Testing

    Current

  6. Resolved

    Not reached

  7. Monitored

    Not reached

A proposal is being tested against reality.

WHAT WOULD CHANGE THIS STATUS?

Logged classroom temperatures from both shaded and unshaded rooms across a full hot term. A consistent reduction would move this to Resolved; no difference would record the shading approach as unsuccessful.

Every record states in advance what evidence would move it. A status is a current reading of the evidence, not a verdict.

Local context

OBSERVATION

Afternoon classroom temperatures make the final teaching hours unproductive. Air conditioning is not affordable to run.

Who is affected: Six classrooms in one school (synthetic).

Evidence

Evidence summary: Synthetic indoor temperature logs; reviewed.

Evidence here does not mean absolute truth. It means: a record exists, with a source, a date and a provenance, and it has reached the review stage shown below.

EVIDENCEConfidence: HighReviewed

Indoor and outdoor temperature logging across one hot term.

Source
Science teacher logging project (synthetic)
Evidence submitted
9 Jan 2026
Provenance
Student-run logging with a documented sensor placement plan.
Evidence reviewed
20 Feb 2026

What is needed

  • Passive cooling design
  • Materials sourcing
  • Measurement support
  • Small works budget

Proposed solutions

PROPOSALIn testingProposed 28 Mar 2026

External shading plus night ventilation

What is proposed
Add external shading to west-facing windows and open the building for night flush ventilation.
Why it might work
Logs show heat gain concentrated in the afternoon on west-facing rooms.
Experience / expertise
Passive design architect (synthetic contributor)
Supporting references
Temperature logs.
What needs testing
Two shaded rooms versus two unshaded controls over one term.
Risks / limitations
Night ventilation depends on security arrangements.

Tests

Shading trial running across two rooms.

Retained knowledge — earlier approaches

PROPOSALPartially workedProposed 2 Sept 2025

Reflective roof paint alone

What is proposed
Paint the roof with reflective coating as a single measure.
Why it might work
Assumed roof gain dominated.
Experience / expertise
Remote contributor
Supporting references
General guidance.
What needs testing
Before/after indoor temperature.
Risks / limitations
May underperform where window gain dominates.

Tried · Did not fully work · Here is why

Synthetic logs showed a small reduction in morning temperature but almost none in the afternoon peak, because the dominant gain came through west-facing glazing. Kept visible: useful, but not sufficient alone.

Updates

  1. OBSERVATION· Local contributor

    Afternoon classes reported as unworkable in hot term.

  2. EVIDENCE· Reviewer

    Temperature logs reviewed; west-facing rooms worst.

  3. UPDATE· Reviewer

    Reflective paint recorded as partially working, with reasons.

  4. UPDATE· Local contributor

    Shading and night-ventilation trial started.

Outcome

No outcome recorded yet. This is the current evidence-backed state of the issue, not a final conclusion.

Offer a solution

A proposed solution is not a verified solution. It enters as Solution Proposed and only testing can move it forward. Local people decide what is workable in their context.

State the assumption your proposal depends on.

If nothing could disprove it, it cannot be tested.